AE1800 Series Air Eliminator
![]() |
HOW IT WORKS
The valve and seat assembly inside the air eliminator is connected to a stainless steel float. When there is no liquid in the body of the air eliminator, the float will be in the down position allowing air or other gases in the vessel or piping system to escape. When liquid enters the body, it will lift the float and the valve will be closed off before any liquid can escape.
FEATURES
- All stainless steel body & Internals
- Hardened SST seat (55Rc) for longer service life
- Repairable unit available (AE1800R)
INSTALLATION
The AE1800 should be located at a high point in the system or vessel. The unit must be installed level and upright with flow
upward for the float mechanism to operate. Isolation valves should be installed for ease of maintenance.